Plug-and-play AI solution to detect and quantify PD-L1 (SP263) within predefined RoIs in non-small-cell lung carcinoma (NSCLC)

The first AI solution for PD-L1 supports cancer experts in the challenging assessment of PD-L1 stained lung tissue. It identifies tumorous cells and quantifies them to support scoring. Mindpeak Lung (NSCLC) PD-L1 (SP263) RoI for NSCLC helps to achieve accurate results without the need of manual fine-tuning.

Conformite Europe logo
Mindpeak Lung (NSCLC) PD-L1 (SP263) RoI is available in the EU as a CE-IVD marked medical device. Outside the EU, Mindpeak Lung (NSCLC) PD-L1 (SP263) RoI is Research Use Only, not for use in diagnostic procedures.

Detailed information on Mindpeak Lung (NSCLC) PD-L1 (SP263) RoI

Output

Mindpeak job posting downward arrow

Image analysis consists of the detection and classification of IHC stained tumor cells within predefined regions of interest (ROI). Tumor cells are classified as not-stained (tumor negative) or stained (tumor positive).

A corresponding tumor proportion score (TPS) is provided as the proportion of the number of positive tumor cells divided by the sum of tumor positive and tumor negative cells.

Workflow

Mindpeak job posting downward arrow

Step 1: Retrieve or select an image with the immunohistochemical PD-L1 staining suited for diagnosis and automated
analysis

Step 2: Select regions of interest suited for diagnosis and automated analysis.

Step 3: Mindpeak Lung (NSCLC) PD-L1 (SP263) RoI analyses the regions of interest and calculate the results

Step 4: Review, adjust and correct the results of the automated analysis in an integrated interactive viewer module.

Step 5: Conclude a final diagnostic decision.

Required Software

Mindpeak job posting downward arrow

Mindpeak Lung (NSCLC) PD-L1 (SP263) RoI is a stand-alone software module for automated image analysis. For interaction with the medical device it must be integrated into an interactive image viewer software that allows the user to manually select or correct regions of interest for analysis with the medical device.

Required Hardware

Mindpeak job posting downward arrow

Mindpeak Lung (NSCLC) PD-L1 (SP263) RoI runs as a web service either in the cloud or on a dedicated on-premise server in the laboratory network. The cloud variant is specified and provided by Mindpeak or distribution partners and requires no additional hardware by the user. For minimum requirements for an on-premise solution, please contact us.

Supported samples

Mindpeak job posting downward arrow

The medical device supports the staining of the VENTANA PD-L1 (SP263) assay.

Performance

Mindpeak job posting downward arrow

In conclusion of the identification, review, assessment, and analysis of the performance of the medical device, the medical device is considered to conform to the general safety and performance requirements according to the IVDD. For more information, please click here to see our study results.

Button TextGet in touch to find out more

Detection and quantification of lung cancer cells

Identification & Quantification

Mindpeak Lung (NSCLC) PD-L1 (SP263) RoI detects and classifies cells into positively stained tumor and unstained tumor cells. One of its great advantages is its ability to differentiate between tumorous and non-tumorous structures, improving your scoring in the tumor microenvironment.

RoI

With Mindpeak Lung (NSCLC) PD-L1 (SP263) RoI you can manually choose the region of your interest on the whole slide
image allowing for automated PD-L1 quantification of specific tumor subpopulations.

Lab Independent

The reliability of Mindpeak Lung (NSCLC) PD-L1 (SP263) RoI is unique: it provides accurate results even in challenging
contexts as it was developed with typical lab-specific variations in mind, such as slide preparation, staining and imaging

Easy Integration

Mindpeak Lung (NSCLC) PD-L1 (SP263) RoI supports a broad range of scanners and can easily be integrated into existing workflows

Find out how Lung (NSCLC) PD-L1 (SP263) RoI can work for you

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Mindpeak Breast IHC being displayed on a monitor

Page Not Found

The page you are looking for doesn't exist or has been moved. Please return to the homepage
Mindpeak Homepage