Breast | IHC quantification | Ki-67

Plug-and-play AI solution to detect and quantify Ki-67 within predefined RoIs of breast cancer tissue

Mindpeak Breast Ki-67 RoI is a software for automated image analysis of digital histopathology images of human invasive mamma carcinoma tissue samples. It is a stand-alone software module that supports the analysis of digital images acquired by scanning the fixed and Ki-67 stained samples of invasive ductal and lobular carcinoma without the need for manual fine-tuning it to your lab.

Conformite Europe logo
Mindpeak Breast Ki-67 RoI is available in the EU as a CE-IVD marked medical device. Outside the EU, Mindpeak Breast Ki-67 RoI is Research Use Only, not for use in diagnostic procedures.

Detailed information on Breast Ki-67 RoI

Output

Mindpeak job posting downward arrow

Image analysis consists of the detection and classification of IHC stained tumor cells within predefined regions of interest (ROI). Tumor cells are classified as not-stained (tumor negative) or stained (tumor positive). A corresponding proliferation score is provided as the proportion of the number of tumor positive cells divided by the sum of tumor positive and tumor negative cells.

Workflow

Mindpeak job posting downward arrow

Step 1: Retrieve or select an image with the immunohistochemical Ki-67 staining suited for diagnosis and automated analysis.

Step 2: Select regions of interest suited for diagnosis and automated analysis.

Step 3: Mindpeak Breast Ki-67 RoI analyses the regions of interest and calculates the results.

Step 4: Review, adjust and correct the results of the automated analysis in an integrated interactive viewer module.

Step 5: Conclude a final diagnostic decision.

Required Software

Mindpeak job posting downward arrow

Mindpeak Breast Ki-67 RoI is a stand-alone software module for automated image analysis. For interaction with the medical device it must be integrated into an interactive image viewer software that allows the user to manually select or correct regions of interest for analysis with the medical device.

Required Hardware

Mindpeak job posting downward arrow

Mindpeak Breast Ki-67 RoI runs as a web service either in the cloud or on a dedicated on-premise server in the laboratory network. The cloud variant is specified and provided by Mindpeak or distribution partners and requires no additional hardware by the user. For minimum requirements for an on-premise solution, please contact us.

Supported samples

Mindpeak job posting downward arrow

The medical device supports the staining of the MIB-1 pharmDx assay from Agilent Dako and the 30-9 antibody assay from Roche Diagnostics.

Performance

Mindpeak job posting downward arrow

In conclusion of the identification, review, assessment, and analysis of the performance of the medical device, the medical device is considered to conform to the general safety and performance requirements according to the IVDD. For more information, please click here to see our study results.

Button TextGet in touch to find out more

Find out how Breast Ki-67 Rol can work for you

Identification & Quantification

Mindpeak Breast Ki-67 RoI detects and classifies cells into positively stained tumor and unstained tumor cells. One of its
great advantages is its ability to differentiate between tumorous and non-tumorous structures, improving your scoring in the tumor microenvironment.

RoI

With Mindpeak Breast Ki-67 RoI you can manually choose the region of your interest on the whole slide image allowing for automated Ki-67 quantification of specific tumor subpopulations.

Lab Independent

The reliability of Mindpeak Breast Ki-67 RoI is unique: it provides accurate results even in challenging contexts as it was developed with typical lab-specific variations in mind, such as slide preparation, staining and imaging.

Easy Integration

Mindpeak Breast Ki-67 RoI supports a broad range of scanners and can easily be integrated into existing workflows.

Find out how Breast Ki-67 RoI can work for you

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Mindpeak Breast IHC being displayed on a monitor

Page Not Found

The page you are looking for doesn't exist or has been moved. Please return to the homepage
Mindpeak Homepage